Generator Changeover Switch Systems
Manual changeover switches, automatic transfer switches and integrated generator + battery backup designs — installed safely and to standard.
A generator changeover system is the bit of wiring that lets you safely connect a backup generator to your switchboard during a grid outage — without back-feeding the grid (which is dangerous and illegal). Done properly, changeover is either a manual switch you flip during a blackout, or an automatic transfer switch (ATS) that handles it without you. We install both, and integrate generators with battery systems where that combination makes sense.
Manual vs automatic changeover
Manual changeover is simpler and cheaper — a clearly labelled switch in the switchboard area that you operate during an outage. Automatic transfer switches detect grid loss and switch over without intervention, with or without auto-starting the generator. ATS is the right call if you're often away from home, run a business from your property, or need critical loads (medical, dairy, cool rooms) to ride through outages without intervention.
- Manual changeover: low cost, simple, requires you on-site
- Automatic transfer switch (ATS): hands-off, faster, more expensive
- Auto-start ATS: also starts the generator without intervention
Why proper changeover wiring matters
Back-feeding the grid from a generator is a serious safety hazard — it can energise downed lines that power crews are working on. A compliant changeover system makes back-feed physically impossible. Every changeover install we do is wired and labelled to Australian standards with mechanical or electrical interlocks preventing simultaneous grid and generator connection.
Generator + battery hybrid backup
If you have or are planning a battery system, integrating a generator multiplies the reliability. The battery handles short outages silently; the generator only fires up for long or heavy outages. Selectronic SP PRO and Victron MultiPlus/Quattro handle this elegantly with auto-start generator support built in.
Frequently Asked Questions
What's a generator changeover switch?
A switch in your switchboard that disconnects your home from the grid and connects it to a generator instead — making it physically impossible to back-feed the grid (which is dangerous and illegal).
Do I need an electrician to install a changeover switch?
Yes — it's switchboard work that has to be done by a licensed electrical contractor to Australian standards. DIY changeover wiring is dangerous and uninsurable.
What size generator do I need with changeover?
Depends on the loads you want to back up. Essential-circuits backup typically needs 3–5 kVA; whole-home with AC and electric cooking needs 10 kVA+.
Can I run my battery and generator together?
Yes — modern inverter-chargers (Selectronic SP PRO, Victron MultiPlus/Quattro) integrate generators automatically. Solar and battery handle normal operation; the generator only runs when needed.
Manual or automatic changeover — which should I choose?
Automatic if you're often away, have a business or critical loads. Manual if you're home most of the time and want the cheapest compliant option.