Generator + Battery Backup — The Real Blackout Solution
Battery storage handles short outages silently. A properly integrated auto-start generator handles the long ones. Together they deliver grid-equivalent uptime without grid dependency.
Battery-only backup is great until the outage runs longer than the battery. Generator-only backup is great until you're not home to start it. The right answer for serious backup — particularly on rural and hinterland properties — is both, properly integrated, so the battery handles short and frequent outages silently and the generator takes over automatically for long ones.
How integrated battery + generator works
The inverter-charger monitors battery state of charge during a grid outage. The battery carries the home for as long as it can. If SoC drops to the configured threshold, the inverter triggers the generator via two-wire auto-start, the generator runs, bulk-charges the battery and supports house loads, then shuts down once SoC targets are met. You don't touch anything. The whole sequence is automatic and logged.
- Battery handles short outages silently — no fuel, no noise
- Generator auto-starts on low SoC for long outages
- Configurable thresholds, run windows and quiet hours
- Bulk charge then shutdown — no all-night idle running
Sizing the generator vs sizing the battery
A larger battery means the generator runs less often. A larger generator means faster recovery from a deep discharge. The economic balance depends on how often the grid is out at your address — high frequency, short duration favours bigger battery; low frequency, long duration favours bigger generator. We size both against actual outage data for your area.
- Battery sized for typical outage duration in your area
- Generator sized to inverter-charger's bulk charge current
- Fuel tank sized for realistic long-outage scenarios
Essential circuit design
Most backup systems are sized for essential circuits, not whole-home. Critical loads (refrigeration, lighting, internet/comms, a few power points, sometimes the AC and well pump) are put on a backup sub-board fed from the inverter's backup output. Non-essential circuits stay on the main board and lose power during outages.
- Essential sub-board separated from main switchboard
- Critical loads identified with the homeowner
- Surge headroom for fridge compressors and AC start
- Whole-home backup option on larger systems
Rural and acreage configurations
Rural properties usually already have a generator — we integrate it rather than replace it. On a typical rural install we add auto-start wiring, a fuel-level sensor where supported, and configure the inverter to use the existing generator as the safety net. Run hours drop dramatically once the battery is in the picture.
Compliance and safety
Electrical work by Solar Repair Co (Elec. Lic. 1510704); SAA accredited installers. All backup systems are installed to AS/NZS 3000 (wiring rules) and AS/NZS 5139 (battery installations), with the battery component signed off by an installer holding current SAA battery accreditation. Generator integration follows manufacturer specifications. Backup sub-boards are clearly labelled, change-over switching is engineered (not improvised), and the install is documented with a single-line diagram and operator handover.
Frequently Asked Questions
Why not just use a generator?
Generators are great for long outages but noisy, fuel-dependent, and need someone to start them. Battery-only handles the short and frequent outages silently. Together they cover everything.
Can I use my existing generator?
Usually yes, if it has (or can have) two-wire auto-start. We integrate existing diesel and petrol generators on most rural installs.
How big a generator do I need?
Sized to the inverter-charger's bulk charge current plus expected concurrent house load. For most acreage installs that's 6–12 kVA — much smaller than running the whole house off the genset alone.
Will the generator start automatically when I'm not home?
Yes — that's the whole point. The inverter controls the generator based on battery state of charge with no user intervention.
How loud is generator backup?
Modern enclosed diesel generators run around 60–70 dB at 7 metres. With the battery carrying short outages, the generator only runs during long ones — typically a fraction of total outage time.
Can this work fully off-grid?
Yes — the same architecture (battery + auto-start generator) is exactly how off-grid systems are built. See our off-grid pages for stand-alone designs.